| [803] | 1 |  | 
|---|
 | 2 | In the Dell PowerEdge SC1435 servers delivered July 2008, | 
|---|
 | 3 | there are several BIOS settings that need to be frobbed on setup. | 
|---|
 | 4 |  | 
|---|
 | 5 | in the setup screen at F2: | 
|---|
 | 6 | - CPU -> Virtualization Technology: on | 
|---|
 | 7 | - Boot Sequence: disable NIC | 
|---|
 | 8 | - Integrated Devices -> Embedded Gb NIC: turn off PXE | 
|---|
| [1566] | 9 | - Serial Communication: | 
|---|
 | 10 |   - Serial Communication: On with Console Redirection via COM2 | 
|---|
 | 11 |   - External Serial Connector: COM1 | 
|---|
 | 12 |   - Failsafe Baud Rate: 57600 | 
|---|
 | 13 |   - Remote Terminal Type: VT100/VT220 | 
|---|
 | 14 |   - Redirection After Boot: Disabled | 
|---|
| [803] | 15 |  | 
|---|
 | 16 | in the setup screen for remote management, at Ctrl-E: | 
|---|
| [1537] | 17 | - Turn on IPMI over LAN | 
|---|
| [803] | 18 | - IP is (main IP) =~ s/18.181.0/10.5.128/ | 
|---|
 | 19 |   e.g. 10.5.128.221 for citadel-station == 18.181.0.221 | 
|---|
| [925] | 20 | - netmask is 255.255.0.0 | 
|---|
| [928] | 21 | - Set the password to the XVM root | 
|---|
| [803] | 22 |  | 
|---|
| [3024] | 23 | All of these settings are reflected on all 8 servers in the production | 
|---|
| [928] | 24 | cluster. | 
|---|
| [926] | 25 |  | 
|---|
 | 26 | In the debian installer: | 
|---|
 | 27 |  - 500M for /boot in raid1 of sda1, sdb1 | 
|---|
 | 28 |  - rest for LVM in raid1 of sda2, sdb2 | 
|---|
 | 29 |   - 50G / | 
|---|
 | 30 |   - 25G swap | 
|---|
 | 31 |  - install a vanilla kernel, not xen; | 
|---|
 | 32 |    will install xen hypervisor from backports in our later custom install. | 
|---|
 | 33 |  | 
|---|
| [3024] | 34 |  | 
|---|
 | 35 | Currently allocated backend IPs: | 
|---|
 | 36 |  | 
|---|
 | 37 | 10.5.128.16 c-s | 
|---|
 | 38 | 10.5.128.17 a-s | 
|---|
 | 39 | 10.5.128.18 s-m | 
|---|
 | 40 | 10.5.128.19 a-m | 
|---|
 | 41 | 10.5.128.20 d-o | 
|---|
 | 42 | 10.5.128.21 g-d | 
|---|
 | 43 | 10.5.128.22 b-f | 
|---|
 | 44 | 10.5.128.23 m-a (not installed) | 
|---|
 | 45 |  | 
|---|
 | 46 | 10.5.128.128 RAID group portal | 
|---|
 | 47 | 10.5.128.129 RAID device/management | 
|---|
 | 48 |  | 
|---|
 | 49 | 10.5.128.221 c-s IPMI | 
|---|
 | 50 | 10.5.128.222 a-s IPMI | 
|---|
 | 51 | 10.5.128.223 s-m IPMI | 
|---|
 | 52 | 10.5.128.224 a-m IPMI | 
|---|
 | 53 | 10.5.128.225 d-o IPMI | 
|---|
 | 54 | 10.5.128.226 g-d IPMI (currently unplugged) | 
|---|
 | 55 | 10.5.128.227 b-f IPMI | 
|---|
 | 56 | 10.5.128.228 m-a IPMI (not configured) | 
|---|
 | 57 |  | 
|---|
 | 58 | 10.6.128.16 c-s | 
|---|
 | 59 | 10.6.128.17 a-s | 
|---|
 | 60 | 10.6.128.18 s-m | 
|---|
 | 61 | 10.6.128.19 a-m | 
|---|
 | 62 | 10.6.128.20 d-o | 
|---|
 | 63 | 10.6.128.21 g-d | 
|---|
 | 64 | 10.6.128.22 b-f | 
|---|
 | 65 | 10.6.128.23 m-a (not installed) | 
|---|
 | 66 |  | 
|---|
 | 67 | 10.6.128.129 RAID device/management | 
|---|
 | 68 |  | 
|---|
 | 69 | 10.6.128.229 g-d IPMI (temporary hardware) | 
|---|