| 2 | In the Dell PowerEdge SC1435 servers delivered July 2008, |
|---|
| 3 | there are several BIOS settings that need to be frobbed on setup. |
|---|
| 4 | |
|---|
| 5 | in the setup screen at F2: |
|---|
| 6 | - CPU -> Virtualization Technology: on |
|---|
| 7 | - Boot Sequence: disable NIC |
|---|
| 8 | - Integrated Devices -> Embedded Gb NIC: turn off PXE |
|---|
| 9 | - Serial Communication: |
|---|
| 10 | - Serial Communication: On with Console Redirection via COM2 |
|---|
| 11 | - External Serial Connector: COM1 |
|---|
| 12 | - Failsafe Baud Rate: 57600 |
|---|
| 13 | - Remote Terminal Type: VT100/VT220 |
|---|
| 14 | - Redirection After Boot: Disabled |
|---|
| 15 | |
|---|
| 16 | in the setup screen for remote management, at Ctrl-E: |
|---|
| 17 | - Turn on IPMI over LAN |
|---|
| 18 | - IP is (main IP) =~ s/18.181.0/10.5.128/ |
|---|
| 19 | e.g. 10.5.128.221 for citadel-station == 18.181.0.221 |
|---|
| 20 | - netmask is 255.255.0.0 |
|---|
| 21 | - Set the password to the XVM root |
|---|
| 22 | |
|---|
| 23 | All of these settings are reflected on all 8 servers in the production |
|---|
| 24 | cluster. |
|---|
| 25 | |
|---|
| 26 | In the debian installer: |
|---|
| 27 | - 500M for /boot in raid1 of sda1, sdb1 |
|---|
| 28 | - rest for LVM in raid1 of sda2, sdb2 |
|---|
| 29 | - 50G / |
|---|
| 30 | - 25G swap |
|---|
| 31 | - install a vanilla kernel, not xen; |
|---|
| 32 | will install xen hypervisor from backports in our later custom install. |
|---|
| 33 | |
|---|
| 34 | |
|---|
| 35 | Currently allocated backend IPs: |
|---|
| 36 | |
|---|
| 37 | 10.5.128.16 c-s |
|---|
| 38 | 10.5.128.17 a-s |
|---|
| 39 | 10.5.128.18 s-m |
|---|
| 40 | 10.5.128.19 a-m |
|---|
| 41 | 10.5.128.20 d-o |
|---|
| 42 | 10.5.128.21 g-d |
|---|
| 43 | 10.5.128.22 b-f |
|---|
| 44 | 10.5.128.23 m-a (not installed) |
|---|
| 45 | |
|---|
| 46 | 10.5.128.128 RAID group portal |
|---|
| 47 | 10.5.128.129 RAID device/management |
|---|
| 48 | |
|---|
| 49 | 10.5.128.221 c-s IPMI |
|---|
| 50 | 10.5.128.222 a-s IPMI |
|---|
| 51 | 10.5.128.223 s-m IPMI |
|---|
| 52 | 10.5.128.224 a-m IPMI |
|---|
| 53 | 10.5.128.225 d-o IPMI |
|---|
| 54 | 10.5.128.226 g-d IPMI (currently unplugged) |
|---|
| 55 | 10.5.128.227 b-f IPMI |
|---|
| 56 | 10.5.128.228 m-a IPMI (not configured) |
|---|
| 57 | |
|---|
| 58 | 10.6.128.16 c-s |
|---|
| 59 | 10.6.128.17 a-s |
|---|
| 60 | 10.6.128.18 s-m |
|---|
| 61 | 10.6.128.19 a-m |
|---|
| 62 | 10.6.128.20 d-o |
|---|
| 63 | 10.6.128.21 g-d |
|---|
| 64 | 10.6.128.22 b-f |
|---|
| 65 | 10.6.128.23 m-a (not installed) |
|---|
| 66 | |
|---|
| 67 | 10.6.128.129 RAID device/management |
|---|
| 68 | |
|---|
| 69 | 10.6.128.229 g-d IPMI (temporary hardware) |
|---|