source: trunk/xvm-host-setup-notes @ 2394

Last change on this file since 2394 was 1566, checked in by broder, 16 years ago

Document config for BIOS accessibility over IPMI

File size: 1.0 KB
RevLine 
[803]1
2In the Dell PowerEdge SC1435 servers delivered July 2008,
3there are several BIOS settings that need to be frobbed on setup.
4
5in the setup screen at F2:
6- CPU -> Virtualization Technology: on
7- Boot Sequence: disable NIC
8- Integrated Devices -> Embedded Gb NIC: turn off PXE
[1566]9- Serial Communication:
10  - Serial Communication: On with Console Redirection via COM2
11  - External Serial Connector: COM1
12  - Failsafe Baud Rate: 57600
13  - Remote Terminal Type: VT100/VT220
14  - Redirection After Boot: Disabled
[803]15
16in the setup screen for remote management, at Ctrl-E:
[1537]17- Turn on IPMI over LAN
[803]18- IP is (main IP) =~ s/18.181.0/10.5.128/
19  e.g. 10.5.128.221 for citadel-station == 18.181.0.221
[925]20- netmask is 255.255.0.0
[928]21- Set the password to the XVM root
[803]22
[928]23All of these settings are reflected on all 4 servers in the production
24cluster.
[926]25
26
27In the debian installer:
28 - 500M for /boot in raid1 of sda1, sdb1
29 - rest for LVM in raid1 of sda2, sdb2
30  - 50G /
31  - 25G swap
32 - install a vanilla kernel, not xen;
33   will install xen hypervisor from backports in our later custom install.
34
Note: See TracBrowser for help on using the repository browser.