Last change
on this file since 990 was
928,
checked in by broder, 16 years ago
|
Update installation notes for the prod cluster
|
File size:
813 bytes
|
Line | |
---|
1 | |
---|
2 | In the Dell PowerEdge SC1435 servers delivered July 2008, |
---|
3 | there are several BIOS settings that need to be frobbed on setup. |
---|
4 | |
---|
5 | in the setup screen at F2: |
---|
6 | - CPU -> Virtualization Technology: on |
---|
7 | - Boot Sequence: disable NIC |
---|
8 | - Integrated Devices -> Embedded Gb NIC: turn off PXE |
---|
9 | |
---|
10 | in the setup screen for remote management, at Ctrl-E: |
---|
11 | - IP is (main IP) =~ s/18.181.0/10.5.128/ |
---|
12 | e.g. 10.5.128.221 for citadel-station == 18.181.0.221 |
---|
13 | - netmask is 255.255.0.0 |
---|
14 | - Set the password to the XVM root |
---|
15 | |
---|
16 | All of these settings are reflected on all 4 servers in the production |
---|
17 | cluster. |
---|
18 | |
---|
19 | |
---|
20 | In the debian installer: |
---|
21 | - 500M for /boot in raid1 of sda1, sdb1 |
---|
22 | - rest for LVM in raid1 of sda2, sdb2 |
---|
23 | - 50G / |
---|
24 | - 25G swap |
---|
25 | - install a vanilla kernel, not xen; |
---|
26 | will install xen hypervisor from backports in our later custom install. |
---|
27 | |
---|
Note: See
TracBrowser
for help on using the repository browser.