1 | |
---|
2 | In the Dell PowerEdge SC1435 servers delivered July 2008, |
---|
3 | there are several BIOS settings that need to be frobbed on setup. |
---|
4 | |
---|
5 | in the setup screen at F2: |
---|
6 | - CPU -> Virtualization Technology: on |
---|
7 | - Boot Sequence: disable NIC |
---|
8 | - Integrated Devices -> Embedded Gb NIC: turn off PXE |
---|
9 | - Serial Communication: |
---|
10 | - Serial Communication: On with Console Redirection via COM2 |
---|
11 | - External Serial Connector: COM1 |
---|
12 | - Failsafe Baud Rate: 57600 |
---|
13 | - Remote Terminal Type: VT100/VT220 |
---|
14 | - Redirection After Boot: Disabled |
---|
15 | |
---|
16 | in the setup screen for remote management, at Ctrl-E: |
---|
17 | - Turn on IPMI over LAN |
---|
18 | - IP is (main IP) =~ s/18.181.0/10.5.128/ |
---|
19 | e.g. 10.5.128.221 for citadel-station == 18.181.0.221 |
---|
20 | - netmask is 255.255.0.0 |
---|
21 | - Set the password to the XVM root |
---|
22 | |
---|
23 | All of these settings are reflected on all 8 servers in the production |
---|
24 | cluster. |
---|
25 | |
---|
26 | In the debian installer: |
---|
27 | - 500M for /boot in raid1 of sda1, sdb1 |
---|
28 | - rest for LVM in raid1 of sda2, sdb2 |
---|
29 | - 50G / |
---|
30 | - 25G swap |
---|
31 | - install a vanilla kernel, not xen; |
---|
32 | will install xen hypervisor from backports in our later custom install. |
---|
33 | |
---|
34 | |
---|
35 | Currently allocated backend IPs: |
---|
36 | |
---|
37 | 10.5.128.16 c-s |
---|
38 | 10.5.128.17 a-s |
---|
39 | 10.5.128.18 s-m |
---|
40 | 10.5.128.19 a-m |
---|
41 | 10.5.128.20 d-o |
---|
42 | 10.5.128.21 g-d |
---|
43 | 10.5.128.22 b-f |
---|
44 | 10.5.128.23 m-a (not installed) |
---|
45 | |
---|
46 | 10.5.128.128 RAID group portal |
---|
47 | 10.5.128.129 RAID device/management |
---|
48 | |
---|
49 | 10.5.128.221 c-s IPMI |
---|
50 | 10.5.128.222 a-s IPMI |
---|
51 | 10.5.128.223 s-m IPMI |
---|
52 | 10.5.128.224 a-m IPMI |
---|
53 | 10.5.128.225 d-o IPMI |
---|
54 | 10.5.128.226 g-d IPMI (currently unplugged) |
---|
55 | 10.5.128.227 b-f IPMI |
---|
56 | 10.5.128.228 m-a IPMI (not configured) |
---|
57 | |
---|
58 | 10.6.128.16 c-s |
---|
59 | 10.6.128.17 a-s |
---|
60 | 10.6.128.18 s-m |
---|
61 | 10.6.128.19 a-m |
---|
62 | 10.6.128.20 d-o |
---|
63 | 10.6.128.21 g-d |
---|
64 | 10.6.128.22 b-f |
---|
65 | 10.6.128.23 m-a (not installed) |
---|
66 | |
---|
67 | 10.6.128.129 RAID device/management |
---|
68 | |
---|
69 | 10.6.128.229 g-d IPMI (temporary hardware) |
---|