Last change
on this file since 1895 was
1566,
checked in by broder, 16 years ago
|
Document config for BIOS accessibility over IPMI
|
File size:
1.0 KB
|
Rev | Line | |
---|
[803] | 1 | |
---|
| 2 | In the Dell PowerEdge SC1435 servers delivered July 2008, |
---|
| 3 | there are several BIOS settings that need to be frobbed on setup. |
---|
| 4 | |
---|
| 5 | in the setup screen at F2: |
---|
| 6 | - CPU -> Virtualization Technology: on |
---|
| 7 | - Boot Sequence: disable NIC |
---|
| 8 | - Integrated Devices -> Embedded Gb NIC: turn off PXE |
---|
[1566] | 9 | - Serial Communication: |
---|
| 10 | - Serial Communication: On with Console Redirection via COM2 |
---|
| 11 | - External Serial Connector: COM1 |
---|
| 12 | - Failsafe Baud Rate: 57600 |
---|
| 13 | - Remote Terminal Type: VT100/VT220 |
---|
| 14 | - Redirection After Boot: Disabled |
---|
[803] | 15 | |
---|
| 16 | in the setup screen for remote management, at Ctrl-E: |
---|
[1537] | 17 | - Turn on IPMI over LAN |
---|
[803] | 18 | - IP is (main IP) =~ s/18.181.0/10.5.128/ |
---|
| 19 | e.g. 10.5.128.221 for citadel-station == 18.181.0.221 |
---|
[925] | 20 | - netmask is 255.255.0.0 |
---|
[928] | 21 | - Set the password to the XVM root |
---|
[803] | 22 | |
---|
[928] | 23 | All of these settings are reflected on all 4 servers in the production |
---|
| 24 | cluster. |
---|
[926] | 25 | |
---|
| 26 | |
---|
| 27 | In the debian installer: |
---|
| 28 | - 500M for /boot in raid1 of sda1, sdb1 |
---|
| 29 | - rest for LVM in raid1 of sda2, sdb2 |
---|
| 30 | - 50G / |
---|
| 31 | - 25G swap |
---|
| 32 | - install a vanilla kernel, not xen; |
---|
| 33 | will install xen hypervisor from backports in our later custom install. |
---|
| 34 | |
---|
Note: See
TracBrowser
for help on using the repository browser.